Cord selection is an assembly decision
Measure the installed route from the furniture module to the intended fixed receptacle. Include the cable tray, strain-relief point, bends, service loop and every position of moving furniture. A straight-line dimension across a drawing will usually miss routing obstacles. The correct length reaches without tension but does not leave uncontrolled coils near mechanisms or walking paths.
Read the complete cord marking. UL explains that flexible-cord letter designations communicate construction and intended-use information; SJT and SPT are not interchangeable names for the same product. Record the full type, conductor count, conductor size, plug and length. AWG and square millimeters are different sizing systems and should not be converted into a claim of identical certification.
Gauge is only one element. Terminations, plug, receptacles, protective devices, enclosure, temperature conditions and the evaluated assembly all affect the permitted use. Do not calculate a new product rating from conductor size alone. Specify the rating shown for the exact complete assembly and keep connected loads within it.
Routing is a safety control. OSHA identifies flexible cords as more vulnerable than fixed wiring and highlights strain relief and damage from edges or abrasion. Furniture design should prevent pinching, sharp-edge contact, repeated uncontrolled flexing and tension at terminals. A cord that passes visual inspection at one desk height may fail at another.
Comparison for the specification decision
| Option or question | Best fit | What to verify |
|---|---|---|
| Short fixed route | Furniture close to a known receptacle | Actual routed distance, service access and no tension |
| Longer fixed route | Large tables or distant supply points | Approved length option, voltage performance and cable management |
| Moving desk route | Height-adjustable furniture | Full travel, bend control, moving/fixed transition and strain relief |
| SPT versus SJT example | Only where the exact assembly permits the type | Full marking, construction, plug, conductor data and listing scope |
A controlled planning and approval process
- Locate the supply. Confirm the intended fixed receptacle and whether it moves relative to the furniture.
- Trace the route. Measure the real path through trays and restraints, including bends and service access.
- Check movement. Measure at every intended furniture position and connected-equipment condition.
- Define the load. List connected equipment without exceeding the approved assembly rating.
- Read the designation. Record cord type, conductor count, size, plug, markings and environmental limitations.
- Confirm strain relief. Verify that tension cannot reach terminals or joints.
- Prototype the route. Install the exact cord in production-intent furniture and cycle moving parts.
- Freeze the variant. Put the approved cord and length on the order code, drawing and inspection plan.
Measure a route, not a straight line
The useful length begins at the module's strain-relief exit and ends where the plug can be inserted without tension. A plan-view dimension misses vertical drops, bends around cable trays, travel on an adjustable frame, and the service loop needed to withdraw a module. Use a flexible cord or string along the proposed route, mark both ends, then measure it. Repeat at every moving position and with the furniture in its final relation to the wall or floor box.
Extra length is not automatically safer. A cord that is 1 m (3.3 ft) longer than necessary may be coiled in a tray, snag a drawer, or fall into a chair path. Too little length transfers pulling force to the plug or strain relief. The target is controlled slack: enough for assembly, normal movement, and service, but not an unmanaged loop. Document where surplus cord is retained and the minimum bend space at the module and plug.
Example length worksheet
| Route segment | Example measured allowance | Why it exists |
|---|---|---|
| Module to rear cable tray | 0.35 m (14 in) | Horizontal path and first bend |
| Across tray | 0.80 m (31 in) | Furniture width to the drop point |
| Vertical drop | 0.75 m (30 in) | Tray height to room receptacle |
| Service movement | 0.20 m (8 in) | Allows the module to be lifted for inspection |
| Total before design review | 2.10 m (6.9 ft) | Sum of the real routed segments |
The figures are an illustration, not a universal cord recommendation. A desk against a wall, a conference table fed from a floor box, and a mobile sit-stand workstation create different routes even when they use the same outlet face.
Read the complete cord marking
American Wire Gauge numbers run opposite to physical size: 14 AWG has a larger conductor cross-section than 16 AWG. That comparison alone does not select a cord. Flexible-cord type, conductor count, insulation, temperature and voltage markings, plug, strain relief, and the listing of the finished assembly all matter. The original product records in this catalog show variants such as SPT-2 and SJT; those designations must not be treated as interchangeable options simply because both can contain three conductors.
Voltage drop depends on current, conductor resistance, and the round-trip length of the circuit. Long cords and high current increase the drop, but this page does not prescribe a gauge from a generic formula because the finished furniture unit has an approved construction and rating. Use calculations to identify a potential problem, then select a documented assembly rather than replacing its cord in the field. A heavier conductor also does not raise the receptacle, plug, protection device, or furniture unit rating.
Separate three length cases in purchasing
- Fixed cabinet: control the wall gap and avoid surplus cord behind drawers or appliance ventilation.
- Large conference table: locate the floor box before freezing the cord exit; a centered box and an end-fed box require different drops.
- Height-adjustable desk: measure at minimum and maximum height, then test the transition between moving top and fixed building supply.
Write cord length from defined reference points. “Two-meter cord” is ambiguous if one supplier measures the visible flexible portion while another includes the plug and molded entry. State the allowed tolerance, cord type, conductor construction, plug designation, color, and exit direction. If multiple variants share one product face, give each a distinct order code so a 1.5 m (4.9 ft) cord cannot be substituted for a 2 m (6.6 ft) cord unnoticed.
Test forces that the drawing cannot show
Place the furniture in the worst permitted location and insert the plug. The cord should not lift the plug, pull the module sideways, rub a sharp edge, or become the travel stop for a moving desk. Operate drawers and height mechanisms while watching the complete route. Then move the furniture through its expected cleaning or service motion. If the cord becomes taut before that motion is complete, change the route or approved length rather than adding an extension cord.
Inspect the first production units for molded-entry orientation and usable length, not just the printed jacket. A plug molded at a right angle can save depth in one room but point the cord into an obstruction in another. The acceptance sample should therefore include the actual plug body and strain relief, with its route shown on the furniture drawing.
Real product paths to use as configuration references
These records show why cord configuration must stay tied to the exact model rather than a generic purchasing line:
- YY131 recessed outlet: the record includes more than one source-listed cord construction, so the variant matters
- YY132-01 recessed outlet: a different recessed model that needs its own drawing and cord confirmation
- YY180-03 grommet outlet: a grommet format with a different routing and retention geometry
These links identify real catalog records, not automatic recommendations. The linked models illustrate recorded cord variants; confirm the exact usable length, cord marking, and plug on the quotation.
Common mistakes to prevent
- Measuring a straight line: The installed path includes bends, trays and service access
- Selecting gauge alone: Cord type, terminations and assembly ratings still control
- Treating cord letters as decoration: The complete designation communicates construction and use
- Leaving a tight cable: Movement can pull terminals or unplug the unit
- Leaving uncontrolled coils: Loops can snag mechanisms or create poor housekeeping
- Changing the cord after approval: The certification and thermal review may no longer match
Have a licensed electrician confirm the final cord and field connection against the applicable local rules.
Related planning guides
Frequently asked questions
How much extra cable length should I allow?
There is no universal extra-length allowance. Measure the actual routed path, include approved bends, restraints, service access and every moving position, then select an offered length that reaches without tension or uncontrolled coils. Confirm the route in a physical prototype and follow the module and furniture instructions.
Does a larger wire gauge allow a higher outlet rating?
No. Conductor size is only one part of the assembly. The plug, receptacles, terminals, protective components, enclosure and certification scope also matter. Use the rating documented for the exact complete product. A conductor substitution or larger gauge does not authorize a higher load.
Are SJT and SPT cords interchangeable?
No. They are different flexible-cord designations with different construction information. The correct type is the one included in the approved product configuration and suitable for the installation conditions. Record the complete marking and do not substitute cord families based on appearance or conductor size alone.
How should cable length be checked on a sit-stand desk?
Route the exact production cord with the desk fully assembled, then move the desk through its entire intended range while observing every fixed-to-moving transition. Check for tension, loops, pinch points, abrasion and interference with user cables. Repeat after representative equipment is connected.
Can the supplied cord be shortened on site?
Do not cut, splice or reterminate a supplied cord unless the manufacturer’s instructions and the applicable approval explicitly permit it. Such a change can alter strain relief, polarity, grounding, markings and certification. Order the required factory configuration or obtain a documented approved method instead of improvising a splice inside the furniture.